Tulsa |
Code of Ordinances |
TULSA CODE OF ORDINANCES |
Title 42-A. OIL AND GAS DRILLING IN THE CITY LIMITS |
Chapter 7. ARTIFICIAL PRODUCTION |
§ 703. Pressure gauges on air or gas lifts.
A.
At each well where air or gas lift is used, there shall be placed on the air or gas lift an indicating pressure gauge which shall show the working pressure of air or gas delivered to the well at all times.
B.
When any air or gas is supplied in any air or gas lift line from a source of supply outside the City, one (1) recording pressure gauge which contains charts shall be placed on the line at the point where it enters the City. The charts shall be preserved and open to inspection by the Inspector. On plants or sources of gas lift or air inside the City, a recording pressure gauge shall be placed between the plant and the well or wells served.
C.
All gauges installed on lines shall be tested and corrected every six (6) months.
(Ord. No. 22189, § 1, 1-14-2010)